Choose under cabinet lighting by deciding what needs illumination, measuring the usable cabinet underside, and identifying a practical power source. Linear bars and LED tape suit longer countertop runs; puck lights provide individual pools of light that need careful spacing.
For a manageable first project, start with one preparation area and a compatible plug-in lighting system. Hardwired lighting can provide a tidy permanent installation, but it needs electrical planning and qualified help.
The aim is useful light on the counter with fixtures, reflections, and cables kept under control. Decide on the layout before buying a kit.

Compare the lighting formats
Fixture shape and power source are separate choices. A bar may be plug-in or hardwired; tape typically forms part of a system with a compatible driver and controls.
| Format | Useful planning advantage | What to check |
|---|---|---|
| Linear LED bars | Ready-made housings can provide broad coverage | Available lengths, connector space, mounting height |
| LED tape or strip | Low profile and adaptable section lengths | Cut points, driver, channels, wiring layout |
| Puck lights | Individual fixtures fit discrete locations | Beam spread, spacing, reflections, gaps between pools |
| Battery or rechargeable lights | Avoid a new wiring connection | Useful brightness, runtime, charging access, mounting |
Kichler’s guidance distinguishes compact, cuttable tape from rigid lighting offered in predetermined lengths. Neither format is automatically better for every cabinet. Kichler Lighting
Bars: check the whole fixture length
A bar that nearly fits the cabinet may leave no room for its power connector. Confirm the housing dimensions and cable exit before choosing the longest available size.
A diffuser can soften the visible light source, but check the actual beam and reflections on your countertop.
Tape: plan the complete system
Tape needs more than an adhesive strip. Depending on the product, the assembly may include a power supply, connectors, a controller, mounting channels, lenses, and end caps.
Cut only at the indicated locations and confirm whether cut sections can be reconnected or extended. Armacost, for example, states that certain 16-foot kits can be cut and reconnected but cannot be extended beyond the supplied length. Armacost Lighting
Pucks: inspect the spaces between the lights
Pucks may work well for isolated sections, but a row of fixtures does not guarantee an evenly lit counter. Compare beam spread at your cabinet-to-counter distance.
Do not choose spacing from an unrelated kitchen photograph. A different mounting height or beam angle changes how the pools of light overlap.
Choose the power and control method
| Power method | What it simplifies | What it adds to the plan |
|---|---|---|
| Plug-in | Uses a suitable existing outlet | Visible cord route, outlet access, switch placement |
| Hardwired | Can conceal the supply connection | Electrician assessment, local requirements, access |
| Battery or rechargeable | Avoids a mains supply route | Replacement or charging schedule and runtime |
Kichler describes plug-in installations as an option for simpler updates, while noting that cords remain visible and occupy outlets. Kichler Lighting
Plan hardwiring, new outlets, in-wall cable routes, and changes to switches with a qualified electrician. Local permit and inspection requirements vary.
For low-voltage lighting, match the light, driver, and controller voltage and system requirements. A matching connector shape alone does not establish compatibility.
Decide how you want to operate the lights: a fixture switch, accessible inline control, remote, or compatible wall control. “Dimmable” does not mean every dimmer will work.
Measure each cabinet section
Gather a tape measure, pencil, paper, and removable markers suitable for the cabinet finish.
Measure from the underside, where the light will actually mount:
- Clear width between obstructions.
- Cabinet depth and front-lip height.
- Height from the underside to the countertop.
- Connector clearance at each end.
- Cable routes between cabinets and around interruptions.
- Space and access for the driver or adapter.
Label separate runs rather than drawing one uninterrupted line across a window, range hood, or cabinet partition.
A simple measurement record
| Section | Clear underside width | Obstructions to record | Candidate light length |
|---|---|---|---|
| A: main preparation area | 30 in / 76.2 cm | End connector and side panel | 28 in |
| B: adjacent counter | 24 in / 61 cm | Divider and cable route | 22 in |
| C: short return | 18 in / 45.7 cm | Corner connection | 16 in |
These are hypothetical planning dimensions, assuming the selected system fits with the available end clearance. They are not universal setbacks or recommended product sizes.
Before ordering, substitute actual fixture dimensions or permitted tape cut lengths.

Plan placement around the work surface
Kichler’s cabinet-lighting guidance suggests positioning lights toward the front edge of the cabinet underside. Use this as a starting point, then check the actual fixture, cabinet lip, and countertop. Kichler Lighting
Lighting placed far back may emphasize the backsplash while leaving the front work area less useful. A fixture too far forward can become visible when seated or produce glare.
Test the candidate position safely using the manufacturer’s permitted setup before permanent mounting:
- Look at the preparation surface from a normal standing position.
- Check the view from nearby seating.
- Inspect reflections on polished countertops.
- Compare illumination at the ends and between sections.
- Confirm doors and stored items remain clear of the assembly.
Keep manufacturer-specified distances from heat and moisture. A dry-rated strip should not be treated as splash-rated merely because it is installed in a kitchen.
Reduce distracting reflections
A shiny countertop can reflect individual LED points. Armacost describes COB tape as providing a more continuous luminous line than conventional separated LEDs. A suitable channel and lens may also change the appearance; evaluate the complete assembly. Armacost Lighting
Do not assume that “dot-free” means reflection-free. Fixture position and surface gloss still matter.

Compare light color, output, and dimming
Color temperature describes the appearance of white light, not its brightness. Lower Kelvin values appear warmer; higher values appear cooler. Waveform Lighting
Compare options such as 3000K and 4000K in the actual room, especially beside existing ceiling lights. These are comparison choices, not mandatory kitchen settings.
Check delivered lumens and how the manufacturer expresses output: per fixture, per foot, or for the full kit. Color rendering is another separate specification. If material and food colors matter to you, compare documented CRI information rather than judging from product photographs alone.
For example, Waveform lists output per foot and CRI separately for its residential strips. Waveform Lighting
Dimming can help one installation serve task lighting and softer evening use. Confirm the supported control method and compatible components before buying.
Calculate tape length and load separately
Using the hypothetical light sections above:
Total illuminated length = sum of section lengths
28 + 22 + 16 = 66 in
66 in ÷ 12 = 5.5 ft, approximately 1.68 m.
If the selected tape were rated at an illustrative 3 watts per foot:
Estimated LED load = illuminated length × rated watts per foot
5.5 ft × 3 W/ft = 16.5 W
This example assumes identical tape across all sections. Connecting cables are measured separately and are not added as illuminated tape length.
Use the manufacturer’s wattage chart for the final configuration. Armacost notes that tape power consumption and the power supply’s watt rating are different quantities. Armacost Lighting
Do not choose a driver from this arithmetic alone. Check voltage, supported load range, any specified reserve, maximum run, wire length, and dimming method. Use the system’s approved configuration; there is no universal reserve percentage for every driver. Armacost Lighting
Prepare a complete shopping list
Record quantities for the lights, approved power supply, controls, connectors, mounting parts, channels or lenses, and cable-management accessories.
Before installation:
- Clear and clean mounting surfaces as instructed.
- Confirm screw lengths will not penetrate the cabinet interior.
- Check cable paths before drilling.
- Keep drivers accessible with their required ventilation.
- Check compatibility before cutting or permanently fixing parts.
- Follow the product’s power-isolation and mounting instructions.